K10400 Oxidation Stability of Fuels, Liquid Baths


 

Test Method
Provides an indication of the tendency of gasoline and aviation fuels to form gum in storage. The sample is oxidized inside a stainless steel pressure vessel initially charged with oxygen at 100psi (689kPa) and heated in a boiling water bath. The amount of time required for a specified drop in pressure (gasoline) or the amount of gum and precipitate formed after a specific aging period (aviation fuels) is determined.

Features and Benefits
• Conforms to ASTM D525, D873, ISO 7536 and related specifications

• Available in two, four or six-unit configurations

• Choice of water or solid block heating baths

• Oxidation pressure vessel incorporates burst disk assembly


 

K10400 Oxidation Stability of Fuels, Liquid Baths
Two different models, both equipped with low liquid-level controllers in accordance with the latest ASTM specifications. Two-unit water bath can be flush mounted in a table top if desired, and is equipped with an overflow standpipe/drain to maintain the proper depth when the pressure vessels are inserted, and a plated brass reflux condenser to minimize evaporation loss. The four/six-unit model can be used with water or oil as a bath medium, and has microprocessor temperature control that provides quick temperature stabilization without overshoot. Dual LED displays provide setpoint and actual temperature values in °C/°F format. A built-in overtemperature control circuit interrupts power should the bath temperature exceed a programmed cut-off point. Both models feature double-wall insulated construction with stainless steel tanks, support racks and port covers. Order thermometer separately. The four/six unit model can be ordered with interchangeable racks for performing the ASTM D942, ASTM D323 and D1298 test methods. Please contact your Koehler representative for additional information.

Communications software (RS232, etc.) ramp-to-set and other enhanced features are available as extra cost options. Contact your Koehler representative for information.


Specifications
Conforms to the specifications of: ASTM D525, D873; IP 40, IP 138; ISO 7536; DIN 51780, 51799; FTM 791-3352, 791-3354; NF M 07-012, 07-013

Maximum Temperature
Two-Unit Liquid Bath: 212°F (100°C)
Four/Six-Unit Liquid Bath: 250°F (121°C)


Ordering Information

 

Catalog
Number

Capacity

Electrical Requirements

Heater Range

Dimensions
lxwxh,in.(cm)

K10400

2 vessels

115V 50/60Hz, 17.3A

0-2000W

24x14x24
(61x36x61)

K10402

220-240V 50/60Hz, 9.0A

K10404

4-6 vessels

220-240V 50/60Hz, 18.1A

0-3000W

24x14x29.5
(61x36x75)


Accessories

 

Catalog
Number

Product Description

K10540

Glass Sample Container and Cover with pour out spout

K10510

Gasket.
Replacement composition gasket for K10500 Oxidation Pressure Vessel.

K10551

Pressure Line.
For pressurizing Oxidation Pressure Vessel. 6 ft. (1.83m) long, with quick release coupling for needle valve on pressure vessel and threaded fitting for oxygen tank.

K10556

Oxygen Manifold Pressure Relief System.
Connects to oxygen source to prevent overcharging of vessel. Equipped with relief valve to vent at 125psi and 300 series stainless steel 150psi burst disk assembly. Constructed from 300 series stainless steel. Cleaned for oxygen service.

K10520

Wrench.
For tightening seal on Oxidation Pressure Vessel.

K10530

Table Socket.
Installs in benchtop to aid in tightening seal on Oxidation Pressure Vessel.

K10560

Bronze Tubing.
For connecting pressure recorder to vessel. Flexible seamless helical tubing with protective armor braid and connections. 5 ft (1.52m) long.

K10525

Burst Disk Assembly.
Retrofit kit for Oxidation Pressure Vessel without burst disk assembly.

250-000-22F

ASTM 22F Thermometer
Range: 204 to 218°F

250-000-22C

ASTM 22C Thermometer
Range: 95 to 103°C

308-000-005

Recorder Charts, Pack of 100.

308-001-02R

Recorder Cartridge Pen, Red

308-001-02B

Recorder Cartridge Pen, Blue

 

When inquiring about NIST traceable certified thermometers, please refer to the catalog number for the corresponding thermometer and replace the middle three zeros in the catalog number with 004. Example: 251-000-01C ASTM 1C Thermometer would be 251-004-01C ASTM 1C Certified Thermometer.


 